SKU: S6927
Manufacturer code: 99-34-22-259(PCS01-C014)

Talley (Direct Healthcare Group)

Talley Pulsair Choice Mattress

$5,999.99 $5,999.99

Clear Selections

Earn up to 6,000 Points.

Add to quote Browse the list
Overview:

The Pulsair Choice Alternating Air Mattress is a dynamic pressure relieving system designed for individuals at high risk of pressure injuries. Clinically supported, trialled and tested, the Pulsair Choice offers intelligent automatic pressure relieving support and adjustment through its industry leading 1-in-4- alternating cell cycle.

Description

The Pulsair Choice Mattress is a dynamic alternating air mattress system developed for those at high risk of pressure injuries. It features a unique 1-in-4 cell cycle that ensures 75% body support at all times, while the fourth cell deflates to reduce pressure and encourage tissue reperfusion. This cycle supports patient comfort while helping prevent stimulus-related issues such as muscle spasms.

Its patented Auto Support technology automatically adjusts internal cell pressures in real time – responding to patient movement, weight and positioning without manual intervention. Ortho-Differential Support (ODS) creates firmer edges for transfers and safety, with a softer central zone for comfort.

The multi-stretch mattress cover reduces shear, friction and fluid ingress. It’s also waterproof and vapour permeable to support skin integrity and hygiene.

A silent, lightweight pump unit with hanging brackets and a carry handle enables easy setup and reliable operation. Features like comfort control, low air loss microclimate management and CPR deflation enhance clinical performance and carer convenience.

 

Who it’s for

  • For clients who are at high risk of pressure injuries and require continuous offloading.
  • For therapists wanting a clinically tested, responsive alternating air system for high-needs pressure care.

 

Key features

  • Active 1-in-4 cell cycle – supports 75% of the patient’s body at all times, on groups of three inflated cells, whilst the fourth cell deflates sufficiently to redistribute the pressure and encourage tissue reperfusion. Additional benefits include enhanced patient comfort, less awareness of support surface movement and a reduction of stimulus-related complications such as muscle spasms
  • Tissuegard air cell – ‘Tissuegard’ enables the partial immersion and envelopment of the patient into the support surface, reducing the pressure on the patient’s skin and decreasing the pressure differential between inflated and deflated cells, which helps reduce tissue strain and associated shearing forces
  • Ortho-differential support – ‘ODS’ results in firmer outer edges of the mattress which facilitate patient transfers and provide extra support, safety and comfort for larger or heavier patients. It also creates a softer central area of the mattress, ideal for smaller, lighter patients
  • Auto Support – ‘Auto Support’ automatically adjusts pressure within each of the cells throughout the cycle so that support, posture and therapy are constantly maintained at optimum levels, in response to patient weight, movement and position. Equalisation of cell pressure automatically takes place at each stage of the cycle, again to ensure precise pressure and therapy is applied
  • Comfort control – allows the carer to adjust the comfort setting in either therapy mode to help patient compliance
  • Pressure relieving stretch cover – the multi-stretch cover promotes tissue offloading during cell deflation and reduces shear and friction during patient movement or manual repositioning. The material is waterproof, moisture-vapour permeable and all seams are welded to protect the inside of the mattress from fluid ingress
  • Low air loss – air is released and circulated beneath the mattress cover to reduce humidity and help manage the skin ‘microclimate’ between the patient and the support surface
  • CPR facility – for simple and effective rapid deflation to enable CPR procedures.
  • Cable management system – in-built cable management system to enhance safety and usability in clinical and homecare settings
  • Modular construction – simple to repair and service with all components being replaceable
Specifications Single Long Single King Single Long King Single
Mattress
Safe working load (SWL) 0 – 200 kg 0 – 200 kg 0 – 200 kg 0 – 200 kg
Length 195 cm 208 cm 195 cm 208 cm
Width 88 cm 88 cm 105 cm 105 cm
Depth 18 cm 18 cm 18 cm 18 cm
Weight 8.6 kg 8.6 kg 9 kg 9 kg
No. of cells 30 32 30 32
Pump
Height 23.3 cm 23.3 cm 23.3 cm 23.3 cm
Width 33.5 cm 33.5 cm 33.5 cm 33.5 cm
Depth 16.5 cm 16.5 cm 16.5 cm 16.5 cm
Weight 3.4 kg 3.4 kg 3.4 kg 3.4 kg
Cycle time 16 mins 16 mins 16 mins 16 mins

Pulsair Choice Brochure

Pulsair Choice User Manual

Pulsair Choice Specifications

Talk to us on the phone

Our experienced phone sales team can assist you with any product enquiries and help you make a purchase directly on the phone. We are available anytime between 9am and 5pm, Monday to Friday.

What are the benefits of using a pressure-reducing mattress?

What is the difference between a foam mattress and a hybrid pressure care mattress?

How does an alternating air mattress work?

Who can benefit from using a hybrid pressure care mattress?

How often should foam pressure-reducing mattresses be replaced?

What are the key features of an alternating air mattress?

Can pressure care mattresses be used on any type of bed frame?

What is the difference between low air loss and alternating air mattresses?

Are pressure care mattresses covered by health insurance or NDIS?

How do I maintain and clean an alternating air mattress?