SKU: S9837
Manufacturer code: SPSYS086

Talley (Direct Healthcare Group)

Talley Quattro Sentinel Mattress

$15,999.99

Clear Selections

Earn up to 16,000 Points.

Add to quote Browse the list
Overview:

The Talley Quattro Sentinel Mattress is a bariatric-grade alternating air mattress designed for individuals at high to very high risk of pressure injuries. It delivers advanced pressure redistribution and safety features to support larger individuals across care environments.

Description

The Talley Quattro Sentinel Mattress provides high-level pressure care using a 1-in-4 alternating cell cycle that continuously supports 75% of the body while redistributing pressure and promoting tissue reperfusion. This supports comfort and reduces complications related to prolonged immobility.

Its bariatric-specific design includes Ortho-Differential Support (ODS) for enhanced edge stability, making transfers safer and more supported. Auto Support technology ensures consistent pressure levels by responding to patient weight, movement and posture throughout the cycle.

Therapy modes include continuous low pressure for immersion, maximum inflation for specific care tasks, and comfort control for compliance.

A demand-based Phase Flow pump enhances energy efficiency and minimises noise, while a waterproof, multi-stretch cover protects against shear and fluid ingress.

This mattress is suitable for hospital, home and facility use for those with body weights up to 370kg, who require comprehensive pressure care.

 

Who it’s for

  • For bariatric clients who are at high to very high risk of pressure injuries.
  • For therapists wanting a durable, clinically tested alternating air system with enhanced edge support and therapy modes.

 

Key features

  • Active 1-in-4 cell cycle – supports 75% of the patient’s body at all times, on groups of three inflated cells, whilst the fourth cell deflates sufficiently to redistribute the pressure and encourage tissue reperfusion. Additional benefits include enhanced patient comfort, less awareness of support surface movement and a reduction of stimulus-related complications such as muscle spasm
  • Ortho-differential support – ‘ODS’ results in firmer outer edges of the mattress which facilitate patient transfers and provide extra support, safety and comfort for larger or heavier patients. It also creates a softer central area of the mattress, ideal for smaller, lighter patients.
  • Auto Support – ‘Auto Support’ automatically adjusts pressure within each of the cells throughout the cycle so that support, posture and therapy are constantly maintained at optimum levels, in response to patient weight, movement and position. Equalisation of cell pressure automatically takes place at each stage of the cycle, again to ensure precise pressure and therapy is applied.
  • Reactive therapy – reactive therapy enhances patient immersion and envelopment into the mattress and applies a constant low pressure to the skin and subcutaneous tissue
  • Comfort control – allows the carer to adjust the comfort setting in either therapy mode to help patient compliance.
  • Phase flow – ‘Phase Flow’ pressure control pump operates on demand only, reducing power consumption, noise and extending service life.
  • Continuous low pressure – when in Continuous Low Pressure mode pressure is equalised within the cells to create a reactive therapy surface, allowing greater immersion and envelopment into the mattress and optimum pressure distribution
  • Pressure relieving stretch cover – the multi-stretch cover promotes tissue offloading during cell deflation and reduces shear and friction during patient movement or manual repositioning. The material is waterproof, moisture-vapour permeable and all seams are welded to protect the inside of the mattress from fluid ingress
  • Maximum inflation – inflates the mattress to maximum static pressure for 15 minutes before returning to previous therapy mode, necessary for some nursing procedures when an active support surface is unsuitable
  • Low air loss – air is released and circulated beneath the mattress cover to reduce humidity and help manage the skin ‘microclimate’ between the patient and the support surface.
  • CPR facility – for simple and effective rapid deflation to enable CPR procedures
  • Cable management system – in-built cable management system to enhance safety and usability in clinical and homecare settings

 

Specifications King Single Double
Mattress
Safe working load (SWL) 370 kg 370 kg
Length 200 cm 200 cm
Width 107.5 cm 120 cm
Depth 18 cm 18 cm
Weight 22.4 kg 23.4 kg
No. of cells 17 17
Pump
Height 23.3 cm 23.3 cm
Width 33.5 cm 33.5 cm
Depth 16.5 cm 16.5 cm
Weight 3.4 kg 3.4 kg
Cycle time 16 mins 16 mins

Quattro Sentinel Brochure

Quattro User Guide 

Quattro Sentinel User Manual

Quattro Sentinel Specifications

Talk to us on the phone

Our experienced phone sales team can assist you with any product enquiries and help you make a purchase directly on the phone. We are available anytime between 9am and 5pm, Monday to Friday.

What are the benefits of using a pressure-reducing mattress?

What is the difference between a foam mattress and a hybrid pressure care mattress?

How does an alternating air mattress work?

Who can benefit from using a hybrid pressure care mattress?

How often should foam pressure-reducing mattresses be replaced?

What are the key features of an alternating air mattress?

Can pressure care mattresses be used on any type of bed frame?

What is the difference between low air loss and alternating air mattresses?

Are pressure care mattresses covered by health insurance or NDIS?

How do I maintain and clean an alternating air mattress?